"Genuine Franke Athena Chrome Handle - Cold 3898R SP3898 133.0314.657" has been added to your basket

View basket
 

Genuine Franke Athena Chrome Handle - Cold 3898R SP3898 133.0314.657

SKU: SP3898CHCATH
Genuine Franke Athena 3898R Chrome Cold handle with C letter indice, ideal for replacing a worn or damaged tap handle. 133.0314.657
£25.00
Free UK Delivery
- +

Genuine Franke Athena Chrome Handle - Cold 3898R SP3898 133.0314.657

If your existing cold handle is damaged, loose or showing signs of wear, this genuine replacement provides an easy way to refresh your Franke Athena tap.

Designed specifically as a genuine Franke replacement part, the 3898R handle offers a practical and cost-effective solution compared with replacing the complete tap.

Product details:

  • Genuine Franke replacement part
  • Suitable for Franke Athena Chrome Tap
  • Cold Tap Handle
  • Chrome Finish
  • Part number: 3898R
  • Alternative references: SP3898 / 133.0314.657
  • Also available in Silk Steel and Matt Black

 

How to fit a Kitchen Tap Handle

Before removing the handle, check how it is secured. Most tap handles use one of the following two fixing methods:

Handle secured with a grub screw

Look underneath the handle for a small grub screw. Use a 2 mm Allen key to loosen and remove the screw, then pull the handle away from the tap spindle. Some tap handles may use a 2.5 mm grub screw, although this is less common.

Handle secured with a hidden screw behind the indicator

Some tap handles have a small hot/cold indicator cap on the side of the lever. Carefully remove the indicator using your fingernail or a pair of tweezers to reveal a Phillips (cross-head) screw underneath. Remove the screw, then pull the handle away from the tap spindle.

Fitting the Replacement Tap Handle

1. Ensure the tap valve is in the fully closed position before fitting the new handle.

2. Push the replacement handle onto the valve spindle and check the alignment. The handle should sit in the correct position when the tap is fully closed.

3. If the handle is not aligned correctly, remove it and reposition it by moving it up a notch or two on the valve until it sits correctly.

4. Once aligned, tighten the grub screw or fixing screw until the handle is secure. Do not overtighten, as this may damage the screw or handle.

Franke Athena FAQ's

My Franke Athena tap is leaking from the base of the spout. What do I need to replace?

If your Franke Athena tap is leaking where the spout meets the main body of the tap, the most common cause is worn or damaged O-rings (seals).

In most cases, replacing the O-rings will restore a watertight seal. If the spout itself has become damaged, cracked or has developed a pinhole, the complete spout will need to be replaced.

How do I remove the Franke Athena spout and replace the O-rings?

1. Turn off the water supply to the tap.
2. Unscrew the locking nut at the bottom of the spout by turning it anti-clockwise, then remove it.
3. Pull the spout vertically upwards to remove it from the tap body.
4. Remove the old O-rings and replace them with new ones.  Usually only the black rings needs to be replaced.
5. Apply a small amount of silicone grease to the new O-rings to help protect the seals and ensure smooth spout movement.
6. Refit the spout into the tap body, ensuring it is correctly positioned.
7. Refit and tighten the locking nut securely.
8. Turn the water supply back on and check for leaks.

My Franke Athena spout has pinholes. Can it be repaired?

If your Franke Athena spout has developed pinholes, cracks or other signs of corrosion, it cannot be repaired. We recommend replacing the complete spout to restore the tap and prevent further leaking.

We stock replacement spouts in ChromeSilk Steel / Brushed Nickel & Matt Black, allowing you to replace the damaged spout without replacing the complete tap.

Which valve does my Franke Athena tap need?

Franke Athena taps were fitted with two different valve types. Earlier taps use the SP1212 / 1212R valve, while Franke changed to the SP3819 valve in 2013.

1212R Pre 2013 Valve
1212R Pre 2013 Valve
3819R Post 2013 Valve
3819R Post 2013 Valve

Before ordering, check your original installation guide or the valve currently fitted to your tap to confirm whether you require the SP1212 / 1212R or SP3819.

My Franke Athena tap is dripping from the top of the spout when turned off. What is the problem?

A dripping spout is normally caused by a worn or damaged ceramic valve. Replacing the faulty valve will usually stop the drip and restore normal operation.

It is often recommended to replace both valves at the same time, as they are typically the same age and may have experienced similar wear.

My Franke Athena tap is leaking around the handle. What needs replacing?

Water leaking from beneath the handle or around the top of the tap body is usually a sign that the ceramic valve has failed.

Replacing the valve is the recommended repair.  We stock the Pre 2013 valve and the Post 2013 valve

How do I remove the Franke Athena lever handle?

1. Remove the indicator from the side of the handle.  Something as simple as your finger nail or tweezers can remove the indicator.
2. Using a Phillips screwdriver, remove the screw underneath the indicator.
3. Pull the handle outwards and away from the tap to remove it.

What tools do I need to replace the valve?

Most Franke Athena taps require:

  • A Philips screwdriver to remove the handle.
  • A 17mm spanner or adjustable spanner to remove the valve.
  • Silicone grease (recommended when replacing seals).

My old valve came out with the brass bush attached. What should I do?

On Franke Athena taps, the brass bush can sometimes come out attached to the old valve. The bush can often be separated from the old valve and reused.

1212R Valve in 3408R Bush
1212R Valve in 3408R Bush
3408R Bush
3408R Bush

To remove the old valve from the bush:

  • Apply penetrating oil, such as WD-40, to the valve threads and allow it to soak for several minutes.
  • Hold the brass bush securely using a cloth and adjustable spanner or a soft-jawed vice.
  • Carefully unscrew the valve anti-clockwise.
  • Clean the bush thoroughly before refitting it into the tap.
  • Install the new valve into the bush.

Avoid using excessive force, as this may damage the bush. If the bush cannot be separated from the old valve, it may need replacing. We stock the 3408R replacement bush for the Franke Athena.  There is one bush per valve.

Should I replace one valve or both?

If one valve has failed due to normal wear, the other is often not far behind.

Replacing both hot and cold valves together can save time and help avoid having to carry out another repair shortly afterwards.

How do I know whether it's the hot or cold valve that needs replacing?

It isn't always obvious which valve has failed. Even if the tap seems to be dripping from the hot side, the problem could actually be the cold valve, and vice versa.

The easiest way to find out is to turn off one water supply at a time:

  • Turn off the hot water supply and see if the dripping stops. If it does, you'll need a new hot valve.
  • If it still drips, turn the hot water back on, then turn off the cold water supply. If the dripping stops, you'll need a new cold valve.

If you can't turn the hot and cold supplies off separately, or you're still unsure which valve is causing the problem, we recommend replacing both valves together. They're usually the same age, so replacing both at the same time can save you having to do the job again later.

DIY Repair Guides

Explore our collection of DIY Repair Guides covering common tap repairs, maintenance tips, troubleshooting advice, and step-by-step guides to help you fix everyday tap problems.

Why Buy from TapSparesUK

For over 40 years, TapSpares UK has been designing and manufacturing quality kitchen taps and replacement tap parts. As one of the UK's leading specialists in replacement valves, cartridges, bushes and tap spares, we help homeowners, plumbers and installers repair leaking and dripping taps quickly and cost-effectively. Our parts are manufactured using premium brass and ceramic components for long-lasting performance, helping you save money while reducing waste.

  • Over 40 years of industry expertise.
  • 12-month guarantee on all parts.
  • Premium brass and ceramic construction.
  • Vernier adaptors included where required.
  • Fast, free UK delivery direct from our factory.
  • Trusted by plumbers, installers and homeowners nationwide.
  • Installation guides available for many products.
  • Friendly UK technical support before and after your purchase.

We stock replacement parts for many leading kitchen tap brands, including Perrin & Rowe, Franke, Abode, John Lewis, Howdens, Wren, CDA, Bristan, San Marco and Carron Phoenix.

Not sure which tap spare part you need? Send images of your tap and/or valve via our Identify my tap form.